11/09/2026
Replace the fuses and it'll probably start. 🧰
That was the easy answer. SANY engineer Yang Xiaxi didn't take it.
A dead electric wheel loader, a stopped production line, and a rainy Saturday in Singapore. Yang assessed the fault remotely within an hour and was on site that afternoon. His first step was to isolate the high-voltage system for safety. Only then did he start diagnostics, tracing the fault to a CAN bus short to ground and two blown fuses.
A fuse blows for a reason. So he kept going. With our factory technicians, he tracked down the root cause. The component was replaced, the high-voltage system tested, and the machine went back to full load.
Fast response gets you back to work. The right fix keeps you there.