Mirasol Engineering & Construction

Mirasol Engineering & Construction Mirasol Engineering & Construction is specialized in cell tower design & construction and other telecom's civil works related. Henjie T. Mirasol. Engr.

Overview
Mirasol Engineering & Construction is an engineering office that offers technical services in designing of structures for: cell site, transmission lines, commercial & residential units, and other design works related. As to experiences, it expanded to construction engineering, site management and quality control which are the important tools for the beginner contractors/subcontractors to

complete the site development of a project. In the design of structure, Mirasol Engineering & Construction will give the client the most realistic approach that aim: simplicity, uniformity & creativity with client's cost awareness. Mirasol Engineering & Construction (MEC) is solely managed by Engr. And as the principal designer, his intensive and long years of experiences in the construction engineering, construction management and supervision, technical and design works, the office was first organized and improved last August 30, 2018. Mirasol as to his expertise to structural engineering, was previously the project consultant of San Miguel Corporation-Telco; Subject Matter Expert at Ericsson Philippines; Engineering Head for Aboitiz Infra Capital. His cooperation idealized the project in the utmost of structural design standard practices. MEC approach in structural design emphasized to the elimination of grandeur approach: those design ideas that are irrelevant in the involving theories and principlesโ€”"Cost-centred". Moreover, MEC offers the client the all-wanted construction engineering/management services for their project. History:
10 years ago, Engr. Mirasol have registered this office and then start handle architectural works, plumbing works & fixtures installation, electrical wiring installation, roofing or even a whole house renovation and construction. Other works accepted was supervising the construction of residential buildings from other contractors/builders. Some small project was accepted and contracted by the office, that was the Exhibit Stall in the province of Antique where he first started the business.

17/07/2022

Me in Trigonometry

17/07/2022
How can we design our Columns if 30% of Rebars is the number of our Anchor bolts? We suggest to check every plane therei...
26/04/2022

How can we design our Columns if 30% of Rebars is the number of our Anchor bolts? We suggest to check every plane therein of our column's sections since we have upper & lower limit for the steel-to-concrete ratio๐Ÿ™‚. At least these maintain the ductility of the sections.๐Ÿ™‚

Considering the presence of anchor bolts in the column section, the rebars is first to yield than the failure mechanism of anchor bolt with the concrete.๐Ÿ™‚

Learning in the state-of-the-art๐Ÿ™‚

Pano po ba application ng wind loads or wind pressure sa Self-supporting-tower? Basahin naten ang "definition" neto sa c...
26/04/2022

Pano po ba application ng wind loads or wind pressure sa Self-supporting-tower? Basahin naten ang "definition" neto sa code at isa-isahin ang bawat salita๐Ÿ™‚

Pag maliit na bagay minsan nawawalan na ng gana.๐Ÿ˜ž Pero pano mo ikakabit yung structural bolts mo kung hindi mo alam ang ...
26/04/2022

Pag maliit na bagay minsan nawawalan na ng gana.๐Ÿ˜ž Pero pano mo ikakabit yung structural bolts mo kung hindi mo alam ang tamang length neto? Tapos kapos pla ang threads...ngayon sanda mak-mak yung washers mo๐Ÿ™‚ cost din yun sa dami ng bolt mo๐Ÿ˜ฅ

Sa isang structural bolt meron lng sapat na thread length

Learning in the state-of-the-art๐Ÿ™‚

In the drawing shown, the highlighted is the tower segment that you should be able to adjust its slenderness factor to t...
25/04/2022

In the drawing shown, the highlighted is the tower segment that you should be able to adjust its slenderness factor to the axes in consideration. The key design here is that the legs of that segment are not node-to-node length, but rather the legs of the whole segment. We believed that these were broken down into multiple beams in the geometric process from software's design. If you haven't adjusted the parameter for "Kx, Ky & Kz" like if you're using the software(s); this will go up to 125% or more for the Utility ratio.๐Ÿ™‚ Meaning it will lead to a failure. Take note that the Legs are the resistance for the braces. There's also a rule that the Horizontal member in this section shall be installed, continuously. Beware where to splice.๐Ÿ™‚

Learning in the State-of-the-art๐Ÿ™‚

Alam mo ba na ang Flat Area Surface ng isang Nut ( sa madaling salita, yung size ng nut bawasan ng butas neto) ay may ka...
25/04/2022

Alam mo ba na ang Flat Area Surface ng isang Nut ( sa madaling salita, yung size ng nut bawasan ng butas neto) ay may kadahilanan sa pag dedesign nang iyong Anchor Bolt? Bukod sa kinailangan na maipasa ang bolt size (diameter) neto dahil sa tension ay dapat maipasa din ang Flat Area netong Nut? Dahil maaring mag customize ka ng Washers or sa magandang paraan ay yung Holding Down Plate para habulin ang Flat Area na kulang.๐Ÿ™‚

Meron din maximum and minimum Nut Size na matatagpuan depende sa availability nang iyong supplier/vendor ng anchor bolt. Minsan ay nauuna ang pag design ng tower bago pa magkaroon ng vendor or fabricator neto. Kung gayon ang isang structural engineer ay dapat na magkaroon ng network sa mga supplier or vendor hindi lng sa kapwa nilang designer; para palawakin ang isipan neto at maipili kaagad ang current used na material gaya ng sa anchor bolt; para maiwasan ang pag customize or pagpili sa matataas na size sa pagnegosasyon sa gitna ng fabricator at ng designer at magkaroon ng overweight. Na kadalasan nagkaroon ng problema sa budget at oras ng client kung saan hindi na-iconsidered at kailangan uli pa approved.๐Ÿ™‚

Dahil sa katangian ng plain rounded anchor bolt na kadalasan na ginagamit, yung outside surface neto ay wala gaanong basihan sa pag analyze? Kung hindi ay yung Flat Area ng Nut na mag hohold down at ang haba (ld) ng reinforcement ng iyong concrete column ay siyang mag dectate ng pullout resistance or breakout surface?

Want to know the design of cell tower? Like of 50 meters? From tower down to foundation and its accessories like the sel...
25/04/2022

Want to know the design of cell tower? Like of 50 meters?

From tower down to foundation and its accessories like the selection of structural bolt and anchor bolt?

Learn the contemporary design of anchor bolt even you have missed buying or attending seminars or trainings lecturing the software based analysis and design of anchorage.

Learn the all times state-of-the-art design process that you can understand clearly what's going on in the Concrete Cast-in-place Anchor Bolts

Please leave your comments, open for engineering students and professionals.

25/04/2022

Want to know the design of cell tower? Like of 50 meters?

From tower down to foundation and its accessories like the selection of structural bolt and anchor bolt?

Learn the contemporary design of anchor bolt even you missed buying or attending seminars or trainings with software based design.

Learn the all times state-of-the-art design process that you can understand clearly what's going on in the Concrete Cast-in-place Anchor Bolts

Please leave your comments, open for engineering students and professionals.

Address

Villa Erlinda Subdivision
San Jose
5700

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm

Telephone

+639950330709

Website

Alerts

Be the first to know and let us send you an email when Mirasol Engineering & Construction posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Mirasol Engineering & Construction:

Share