Today ActivitiesHalliburton Sperry Drilling Regional Repair Center 1. Completion of 45° Sharetree Oven movement by the t...
01/02/2024

Today Activities

Halliburton Sperry Drilling Regional Repair Center

1. Completion of 45° Sharetree Oven movement by the teams. Tomorrow plan is to re-route the refrigent piping line ½" & ⅞" with brazing, 4hour vacuum, and new refrigent R404A. Inclusive Testing & Commisioning.

2. Dismantle parts, Oring, Seal of Hydraulic Double Acting Cylinder inclusive inspection of shaft, piston and accesories. Once we get all the summaries, then propose to client for further repair & maintenance action plan.

Halliburton Completion Tools.

1. Completion of Electrical & Air cond installation at new cool room

Halliburton Testing & Subsea GBA

1. Communicate with supplier regarding IECEX/ATEX parts and accesories. Job proceed once we get the Purchase Order from our client.

Supply grounding cable & accesories due to urgent request from offshore team.
21/01/2024

Supply grounding cable & accesories due to urgent request from offshore team.

Inspection hydraulic power pax and actuator of Sperry Drilling MWD Casing pull out. The sympthon is the power pax was cu...
20/01/2024

Inspection hydraulic power pax and actuator of Sperry Drilling MWD Casing pull out. The sympthon is the power pax was cut off while the hydraulic pressure start reach 2000psi.

Earlier observation found bad relay contact, so those equipment will consume high amp thus the thermostat energized and the system cut off.

The relay contact 30A was rare in the market, the we will propose to the client to upgrade the mechanical relay with the Solid State Relay which is able to hold the current up to 40A without mechanical contact.

We able to supply the Atex Certified Instrument Parts with a valid certificate including installation. We follow the sta...
20/01/2024

We able to supply the Atex Certified Instrument Parts with a valid certificate including installation. We follow the standard according regulation

If you have any questions or concerns, please do not hesitate to contact me.
19/01/2024

If you have any questions or concerns, please do not hesitate to contact me.

Today jobTroubleshooting 2 unit x 1hp air cond at client site.1. AC #1 Air cond yellow blinking, not cool-  Measure term...
18/01/2024

Today job

Troubleshooting 2 unit x 1hp air cond at client site.

1. AC #1 Air cond yellow blinking, not cool

- Measure termocouple sensor : OK
- Check Indoor , Compressor Terminal Point : OK
- Check Outdoor Unit : Physically found faulty capacitor of the compressor. Measuring Capacitor fan blower as well. Both Capacitor required new replacement.

2. AC #2 Air Cond Yellow blinking after several minutes

- Measure termocouple sensor : OK
- Check Indoor , Compressor Terminal Point : Not OK. Found minor corroded at LED panel connector. Cleaning using contact cleaner. Now Compressor Terminal Point Triggered. But still not cool.
- Check Outdoor Unit : Measure Compressor Terminal Point, No Voltage. Physically found an indoor to outdoor cable was different type cable. Suspect the cable joined in the middle. Replacement with a new cable.

Replacement Atex certified parts completed with certificate of conformance.
17/01/2024

Replacement Atex certified parts completed with certificate of conformance.

Inspection & Services Air Compressor at Client Site
31/12/2023

Inspection & Services Air Compressor at Client Site

Troubleshooting & Cleaning 110v PCB of ultrasonic cleaner tank. Found some components not functioning. Symptom - Heater ...
19/12/2023

Troubleshooting & Cleaning 110v PCB of ultrasonic cleaner tank. Found some components not functioning.

Symptom - Heater not functioning
Observation - Tank drain leaking

Order replacement parts.

Address

Lot 4015 Jalan Kemunting, Kg Bukit Kuang
Kemaman
24000

Opening Hours

Monday 09:00 - 18:00
Tuesday 09:00 - 18:00
Wednesday 09:00 - 18:00
Thursday 09:00 - 18:00
Saturday 09:00 - 16:00
Sunday 09:00 - 18:00

Telephone

+601157624959

Website

Alerts

Be the first to know and let us send you an email when Kuasa Dinamik Official posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Kuasa Dinamik Official:

Share