09/10/2026
NUM Power Supply Repair β Found Fault, Repaired & Bench Tested!
We do industrial electronic repair. And we demonstrate the benefit of proper fault diagnosis and expert engineering.
Recently our engineer Michael Hilton worked on a NUM MDLL2030Q00 Power Supply Unit (PSU) with an unknown fault.
During initial testing, Michael observed that the contactor was not engaging. Further inspection showed that the unit was contaminated by the environment, causing poor electrical connections and dry solder joints.
Repair Process
Our engineer Michael fully cleaned the unit to remove environmental contamination before repairing the damaged electrical connections and reflowing dry solder joints. He then thoroughly checked and inspected the active, passive and transient components to ensure all possible problems were fixed. Before final workshop testing of the unit, the damaged casing was also repaired. Workshop testing, final
When repairs were completed, the unit was powered up at 415V and tested with a lamp load on the brake circuit.
The results confirmed a 600V DC output and the right AC output. The unit successfully passed all tests in our workshop. With the test setup, no further functional testing was possible.
Great effort from Michael, who has been a diligent fault finder and fixer and has restored this unit to a testable and working condition.
At Neutronic Technologies we understand the importance of reliable power supplies to industrial machinery and automation systems. Our experienced engineers work to identify faults, repair damaged components and help businesses minimise costly downtime.
Having trouble with an industrial power supply?
Learn About Our Power Supply Repair Services:
https://neutronictechnologies.com/power-supply-repairs/