19/06/2026
Repaired and serviced a NAD 3020 integrated amp.
Fault reported / work requested:-
Lost volume.
Checked general operation OK before proceeding - coonfirmed the fault reported.
Removed the top and bottom covers for access.
Visual inspection for disstressed/degrading components, solder joints, loose wiring , fuses, etc.
Fault traced to the slow start/fast off circuit - replaced 3x capacitors, 1x resistor and 1x diode. Unit now giving audio as per normal operation with 15 second delayed start.
Also replaced all 4x 2,200uF main power filter capacitors with 2x 4,700uF/35V; replaced 2x other critical capacitors which commonly fail.
Checked all DC voltages OK.
Checked midpoint and quiescent OK.
Checked operation of all inputs and outputs OK.
Checked output voltage, symmetry and channel balance OK.
Refitted covers for final test.