🔧 Hitachi HI VISION Avius Repair CaseHardware error at startup? Our engineers identified power supply and CELL board fau...
2026/11/12

🔧 Hitachi HI VISION Avius Repair Case

Hardware error at startup? Our engineers identified power supply and CELL board faults.

✅ Power supply replaced
✅ CELL board replaced
✅ System restored to normal operation

Having issues with your ultrasound equipment? We provide professional ultrasound repair services for multiple brands.

📩 Contact us for reliable repair solutions!

Guangzhou Rongtao Medical Tech LTD

📲 WhatsApp: +86 19566042918
🌐 www.rongtaomedical.com
📧 [email protected]

🔧 Siemens S1000 – Professional Ultrasound System RepairExperiencing no image or waveform in M-mode, or unable to switch ...
2026/11/12

🔧 Siemens S1000 – Professional Ultrasound System Repair

Experiencing no image or waveform in M-mode, or unable to switch to the 14L5 probe?

Our engineers identified a power supply issue. After replacing the PSA power supply, the system was restarted and returned to normal operation.

✅ Professional fault diagnosis
✅ Reliable component replacement
✅ Tested and restored to normal operation

Need help with your ultrasound system? We provide professional repair services for Siemens and other major ultrasound brands.

📲 WhatsApp: +86 195 6604 2918
📧 Email: [email protected]
🌐 www.rongtaomedical.com

Guangzhou Rongtao Medical Tech LTD

🔧 Philips EPIQ C6-2 Ultrasound Probe Repair⚠️ Problem: Severely aged and yellowed cable.🛠️ Solution: Cable and strain re...
2026/11/10

🔧 Philips EPIQ C6-2 Ultrasound Probe Repair

⚠️ Problem: Severely aged and yellowed cable.

🛠️ Solution: Cable and strain relief replacement.

✅ Result: Successfully repaired and restored!

💙 Don't replace it — repair it! We provide professional ultrasound probe repair services for GE, Philips, Siemens, Mindray, Canon and more.

📩 Contact us for your repair needs!

📱 WhatsApp: +86 19566042918
🌐 www.rongtaomedical.com
📧 [email protected]

🔧 GE RM6C Ultrasound Probe Repair – Successfully Restored!⚠️ Issue: Image interference caused by cable failure and an ag...
2026/11/10

🔧 GE RM6C Ultrasound Probe Repair – Successfully Restored!

⚠️ Issue: Image interference caused by cable failure and an aged oil bag.

🛠️ Solution: Cable repair & oil bag replacement.

✅ Result: Image quality restored and probe functioning normally!

💙 We provide professional ultrasound probe repair services for GE, Philips, Siemens, Mindray, Canon, Samsung and more!

📩 Have a faulty probe? Contact us for a repair solution!

📱 WhatsApp: +86 19566042918
🌐 www.rongtaomedical.com
📧 [email protected]

🔧 GE C1-6-D Ultrasound Probe Successfully Repaired!Image loss caused by a damaged transducer head? We fixed it!✅ Fault: ...
2026/11/04

🔧 GE C1-6-D Ultrasound Probe Successfully Repaired!

Image loss caused by a damaged transducer head? We fixed it!

✅ Fault: Image loss
🔧 Repair: Transducer head replacement
🎯 Result: Image successfully restored!

Don't replace your probe too soon. Let our professional team help you restore it!

We also provide repair services for various ultrasound probe brands and models.

📲 WhatsApp: +86 195 6604 2918
📧 Email: [email protected]
🌐 www.rongtaomedical.com

Guangzhou Rongtao Medical Tech LTD

🔧 PHILIPS L12-5 Probe RepairImage loss caused by a damaged transducer head. Replaced the damaged head and restored norma...
2026/11/04

🔧 PHILIPS L12-5 Probe Repair

Image loss caused by a damaged transducer head. Replaced the damaged head and restored normal imaging!

Have other faulty ultrasound probes? We repair a wide range of ultrasound probe brands and models!

📩 Contact us for repair solutions and quotations.

Guangzhou Rongtao Medical Tech LTD

📲 WhatsApp: +86 195 6604 2918
📧 [email protected]
🌐 www.rongtaomedical.com

2026/11/04

🔧 Ultrasound Probe Repair Training | Learn by Doing!

🌍 From theory to hands-on practice!

At Rongtao Medical, we provide practical ultrasound probe repair training for international customers.

✅ Real Probe Fault Diagnosis
✅ Engineer-Led Repair Demonstrations
✅ Hands-on Disassembly & Reassembly
✅ Practical Technical Skills Development

💡 Real Practice. Professional Guidance. Better Repair Skills.

Looking to improve your ultrasound probe repair capabilities? Join our technical training program!

📩 Contact us for training details!

📲 WhatsApp: +86 195 6604 2918
📧 Email: [email protected]
🌐 www.rongtaomedical.com

🔧 Esaote MyLab 90 | Fan Assembly RepairFault: The fan assembly was not working, causing the system to overheat and shut ...
2026/10/29

🔧 Esaote MyLab 90 | Fan Assembly Repair

Fault: The fan assembly was not working, causing the system to overheat and shut down automatically after running for a period of time.

Diagnosis: No voltage was detected at the fan power cable. The SPS board was identified as the suspected faulty component.

Repair Result: After replacing the SPS board, the fan assembly returned to normal operation. ✅

Need reliable ultrasound equipment repair support? Contact Rongtao Medical today!

📩 Email: [email protected]
📲 WhatsApp: +86 195 6604 2918
🌐 Website: www.rongtaomedical.com

Guangzhou Rongtao Medical Tech LTD
Your trusted partner for ultrasound repair solutions.

🔧 GE LOGIQ E9 Repair Case | Virtual Interface Only at StartupFault Symptom:The system started normally but displayed onl...
2026/10/29

🔧 GE LOGIQ E9 Repair Case | Virtual Interface Only at Startup

Fault Symptom:
The system started normally but displayed only a virtual interface after entering the ultrasound interface. Probe switching was unavailable.

Diagnosis & Repair:
The issue was traced to an abnormal front-end/rear-end connection, associated with a communication board fault. The MRX board was replaced to resolve the issue.

✅ Repair Result: Fault resolved successfully.

Need reliable ultrasound equipment repair solutions? Contact our team today!

📲 WhatsApp: +86 195 6604 2918
📧 Email: [email protected]
🌐 Website: www.rongtaomedical.com

Guangzhou Rongtao Medical Tech LTD
Your partner in ultrasound repair solutions.

🔧 Siemens VF12-4 Probe Repair CaseFaults: Image shadow and lens bubbles.Our engineers replaced the faulty transducer ele...
2026/10/23

🔧 Siemens VF12-4 Probe Repair Case

Faults: Image shadow and lens bubbles.

Our engineers replaced the faulty transducer element and repaired the cable, successfully restoring the probe.

Need professional ultrasound probe repair support? Contact us today!

Guangzhou Rongtao Medical Tech LTD

📲 WhatsApp: +86 195 6604 2918
📧 Email: [email protected]
🌐 Website: www.rongtaomedical.com

Address

510530
Guangzhou
Room 201, 203, Building C , No. 26, Ningcai Road, Huangpu District

Opening Hours

Monday 09:00 - 19:00
Tuesday 09:00 - 19:00
Wednesday 09:00 - 19:00
Thursday 09:00 - 19:00
Friday 09:00 - 19:00

Telephone

+8619566042918

Alerts

Be the first to know and let us send you an email when Guangzhou Rongtao Medical TECH LTD posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Guangzhou Rongtao Medical TECH LTD:

Shortcuts

Share