06/25/2026
High‑temp gauge tip: don’t size the range so normal operating pressure is near the top of the scale.
Aim to keep normal pressure near the middle of the dial and max expected pressure ≤ ~75% of full scale for better gauge life in elevated‑temperature and pulsating service.