L/C Magnetics Inc.

Call Website Contact the business

L/C Magnetics Inc. L/C Magnetics is a leader in manufacturing custom transformers, inductors, and current limiting reactors.

We design and build a wide variety of air cooled and water cooled magnetic components per specific customer requirements. The past and present principals of L/C Magnetics have a combined experience of more than 60 years in this industry. We have accumulated a vast amount of tooling to quickly respond to new prototypes. Our magnetic components can be as small as 1 oz in weight, or as large as 2000 lbs in weight.

WYE DELTA TRANSFORMER6 KVA, P/N 19343Isolation Transformer, 6 KVA, 3 PH, 60 Hz, P/N 19343Primary: 456/480/504 VAC L-L, 7...
01/09/2024

WYE DELTA TRANSFORMER
6 KVA, P/N 19343

Isolation Transformer, 6 KVA, 3 PH, 60 Hz, P/N 19343
Primary: 456/480/504 VAC L-L, 7.21 Amps, Wye
Secondary (1 to 6): 10 VAC L-L, 346 Amps, Open Delta, 3 PH
Secondary: 120 VAC, 1 Amps, 1 PH
Copper winding construction
Primary copper bus bars are 1/8” x 5/8” with one hole
secondary copper bus bars are 1/4” x 1 1/12” with one hole
Open core and coil: 11”H x 14.5”W x 10”D approximately
Estimated weight: 250 lbs.

Oil-Immersed Power TransformerService Voltage: 6 KV to 35 KVRated Capacity: 30 KVA to 3150 KVAPhase: Single & Three
01/02/2024

Oil-Immersed Power Transformer
Service Voltage: 6 KV to 35 KV
Rated Capacity: 30 KVA to 3150 KVA
Phase: Single & Three

UL / CSA APPROVED TRANSFORMERSSpecifications:UL / CUL / CSA Transformer, 45 KVA, 3 PH, 50/60 Hz, P/N JE-91Primary (H1, H...
12/25/2023

UL / CSA APPROVED TRANSFORMERS

Specifications:
UL / CUL / CSA Transformer, 45 KVA, 3 PH, 50/60 Hz, P/N JE-91
Primary (H1, H2, H3): 480 VAC, 54.1 Amps max, Delta
Taps : +2.5%, + 5%, -2.5%, -5%, -7.5%, -10%
Secondary (X1, X2, X3): 208 VAC L-L, 125 Amps max, Wye with a neutral X0
Enclosure – 28”H x 26”W x 24”D
Insulation – 220°C
Temp Rise – 150
Windings – Aluminum
Seismic – Yes
Weight: 500 lbs.

MILITARY GRADE COMMON MODE 3PH INDUCTOR3 mH, 250 Amps, 400 Hz, P/N JA-08Specifications:Military Grade Common Mode Induct...
12/18/2023

MILITARY GRADE COMMON MODE 3PH INDUCTOR
3 mH, 250 Amps, 400 Hz, P/N JA-08
Specifications:
Military Grade Common Mode Inductor, P/N JA-08
L (1, 2) = 10 uH, 250 Amps
L (3, 4) = 10 uH, 250 Amps
L (5, 6) = 10 uH, 250 Amps
Frequency: 400 Hz
Open core & coil: 6″W x 6″H x 6″D approximately
Encapsulated assembly
Weight: 10 lbs approximately

REPLACEMENT TRANSFORMER 77 VA, P/N 19507Specifications:Dual Secondary Transformer, 77 VA, 1 PH, 60 Hz, P/N 19507Primary ...
12/13/2023

REPLACEMENT TRANSFORMER 77 VA, P/N 19507
Specifications:

Dual Secondary Transformer, 77 VA, 1 PH, 60 Hz, P/N 19507
Primary (1, 2): 220 VAC, 0.35 Amps
Secondary (3, 4): 26 VAC, 1.5 Amps
Secondary (5, 6): 31 VAC, 1.25 Amps
Copper windings
Primary and secondary connections are solder lugs
Open core and coil: 3.75″W x 3″H x 3″D approximately
Estimated weight: 5 lbs.

12 PULSE TRANSFORMER, 300 KVA, P/N MG-01Specifications:12 Pulse Transformer: 300 KVA, 3 PH, 60 Hz, P/N MG-01Primary (X1,...
11/30/2023

12 PULSE TRANSFORMER, 300 KVA, P/N MG-01

Specifications:
12 Pulse Transformer: 300 KVA, 3 PH, 60 Hz, P/N MG-01
Primary (X1, X2, X3): 480 VAC L-L, 360 Amps, no taps
Low Voltage BIL: 10 KV
Secondary 1(H1, H2, H3): 2500 VAC L-L, 35 Amps, Delta
Secondary 2( H4, H5, H6): 2500 VAC L-L, 35 Amps, Wye, neutral is H0
High Voltage BIL: 20 KV
Copper windings
Primary copper bus bars are 1/4” x 1 1/2” with one hole
Secondary copper bus bars are 1/4” x 1” with one hole
Open core & coil, 50”W x 35”H x 22”D
Weight: 2150 lbs.

DELTA WYE TRANSFORMER0.5 KVA, P/N 19202Specifications:• Delta-Wye Transformer, 500 VA, 3 PH, 60 Hz, P/N 19202• Primary: ...
11/22/2023

DELTA WYE TRANSFORMER
0.5 KVA, P/N 19202
Specifications:
• Delta-Wye Transformer, 500 VA, 3 PH, 60 Hz, P/N 19202
• Primary: 480 VAC L-L, 0.6 Amps, Delta
• Secondary: 208 VAC L-L, 1.4 Amps, Wye with a neutral N
• Copper winding construction
• Primary and secondary connections are J-lugs
• Open core & coil: 5″H x 7″W x 7″D

TAP SWITCH TRANSFORMER10 KVA, 1 PH, 50/60 Hz, P/N 18058NSpecifications:• Tap Switch Transformer: 10 KVA, 1 PH, 50/60 Hz,...
11/13/2023

TAP SWITCH TRANSFORMER
10 KVA, 1 PH, 50/60 Hz, P/N 18058N
Specifications:
• Tap Switch Transformer: 10 KVA, 1 PH, 50/60 Hz, P/N 18058N
• Primary: 200/208/220/240 VAC, 50 Amps max
• Secondary: 240 VAC, 41.67 Amps
• One voltmeter installed on the enclosure
• NEMA 1 enclosure
• All connections are inside the enclosure

HIGH FREQUENCY GAPPED INDUCTOR133 mH, 1 Amp, 100 Hz, P/N 18710LSpecifications:High Frequency Gapped Inductor, P/N 18710L...
11/08/2023

HIGH FREQUENCY GAPPED INDUCTOR
133 mH, 1 Amp, 100 Hz, P/N 18710L

Specifications:
High Frequency Gapped Inductor, P/N 18710L
L (1, 2) = 133 mH ± 25 %, 1 Amp
Frequency: 100 Hz
RDC: 1 Ohm max
Open core and coil, 4” H x 4 1/2” W x 4” D
Copper winding construction

MODIFIED CURRENT TRANSFORMER, 2 VA, CURRENT RATIO: 20 TO 5Specifications:Current Transformer, 2 VA, 50/60/400 Hz, P/N 92...
11/02/2023

MODIFIED CURRENT TRANSFORMER, 2 VA, CURRENT RATIO: 20 TO 5
Specifications:

Current Transformer, 2 VA, 50/60/400 Hz, P/N 9269L3
Current Ratio: 20 : 5 Amps
Dimensions: OD = 3.5”, ID= 1.5”, thickness= 1.5”
Insulation level: 600 Volts, 10 KV BIL full wave
20 Amps lead wire: AWG # 10, flexible lead, Black
5 Amps lead wire: AWG # 16, flexible lead, Black, White
Estimated weight: 1 lb.

Address

Anaheim, CA

Opening Hours

Monday 6:30am - 5pm
Tuesday 6:30am - 5pm
Wednesday 6:30am - 5pm
Thursday 6:30am - 5pm

Telephone

+17146244740

Alerts

Be the first to know and let us send you an email when L/C Magnetics Inc. posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to L/C Magnetics Inc.:

Shortcuts

Share