VSR-S
Vane Type Waterflow Alarm
Switch With Re**rd
Features
• Assembled in USA
• 0-90 second field replaceable time delay re**rd
• Easy to read re**rd time delay adjustment k**b
• Fits 1” to 2” CPVC, copper, brass, or iron pipe
• Comes with all necessary paddles
• Two SPDT (form C) contacts
• Weatherproof
• Easy to read wire terminal designations
• 5 year warranty
DESCRIPTION:
The Model VSR-S is a vane type waterflow switch for use on wet
sprinkler systems that use 1” (25mm), 1¼” (32mm), 1½” (38mm) or 2”
(50mm) pipe size. The unit may also be used as a sectional waterflow
detector on large systems.
The unit contains two single pole double throw snap action switches
and an adjustable, instantly recycling pneumatic re**rd. The switches
are actuated when a flow of 10 gallons per minute (38 LPM) or more
occurs downstream of the device. The flow condition must exist for a
period of time necessary to overcome the selected re**rd period.
ENCLOSURE:
The VSR-S switches and re**rd device are enclosed in a general
purpose, die-cast housing. The cover is held in place with two tamper
resistant screws which require a special key for removal. A field
installable cover tamper switch is available as an option which may
be used to indicate unauthorized removal of the cover. See bulletin
number 5401103 for installation instructions of this switch.
Technical Specifications
Service Pressure 300 PSI (20,68 BAR) - UL
Flow Required for
Alarm
10 GPM (38 LPM)
To ensure minimum flow of 10 gpm, a minimum pressure is
required at all sprinklers with a k-factor of 3 or less.
K-3: 10 PSI
K-2.8: 12 PSI
Maximum Surge 18 FPS (5,5 m/s)
Enclosure Die-cast, red powdercoat finish
Contact Ratings
Two sets of SPDT (Form C)
10.0 Amps at 125/250VAC
2.0 Amps at 30VDC Resistive
10 mAmps min. at 24VDC
Conduit Entrances Two 1/2” conduit connections provided. Individual switch
compartments suitable for dissimilar voltages.
Usage
Listed plastic, copper, schedule 40 iron pipe and unlisted riser
assemblies approved by Potter .
Fits pipe sizes - 1”, 1¼”, 1½” and 2”
Note: 12 paddles are furnished with each unit, one for each pipe
size of threaded and sweat TEE, one for 1” CPVC, one for 1”
CPVC (Central), one for 1” threaded Nibco CPVC, and one for
1½” threaded (Japan).
Environmental
Specifications
• NEMA 4/IP65 Rated Enclosure suitable for indoor or
outdoor use with factory installed gasket and die-cast housing when
used with appropriate conduit fitting.
• Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL
Service Use
Automatic Sprinkler NFPA-13
One or two family dwelling NFPA-13D
Residential occupancy up to four stories NFPA-13R
National Fire Alarm Code NFPA-72
For inquiries/information, you may call us at the following numbers;
8285-7080
8658-6372
Mobile/Viber number: 0975-569-1036
Mobile/Viber number: 0917-639-5235
: 0915-925-2309
: 0976-509-6484
Email: [email protected]
[email protected]
[email protected]
Look for Joseph Alvarez or Eli Dee
Website: www.pinoleakpes.com
Everything is here!
°
°
COLOR
-Red
-Yellow
-Green
-Blue
°
°
**ge
**getypevalve **rd